CDRRL - 120975 URETHANE ACCELERATOR
- MSDS: CDRRL
- Manufacturer: PRATT AND LAMBERT INC
- Product Name: 120975 URETHANE ACCELERATOR
- National Stock Number: 8010-00F053561
Product Identification
Product ID:120975 URETHANE ACCELERATOR
MSDS Date:02/09/1995
FSC:8010
NIIN:00F053561
MSDS Number: CDRRL
Responsible Party
WITCHITA, KS 67201-2153
US
Emergency Phone: 716-873-6000/316-733-1361
Info Phone: 316-733-1361/716-873-6000
Cage: PRATT
Contractor
Telephone: 216-566-2902
Cage: 61196
Ingredients
TOLUENE (IARC CARC- GROUP 3) *97-1*
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 10%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
PROPYLENEGLYCOL MONOMETHYL ETHER ACETATE,
CAS: 108-65-6
RTECS: AI8925000
Fraction By Weight: 45%
DIPROPYLENE GLYCOL MONOMETHYL ETHER ACETATE
CAS: 88917-22-0
Fraction By Weight: 5%
DIBUTYLTIN DILAURATE, URETHANE CATALYST
CAS: 77-58-7
RTECS: WH7000000
Fraction By Weight: <5%
OSHA PEL 0.1 MG/CUM (SN)
ACGIH TLV: 0.1 MG/CUM, SN(SKIN)
ACETIC ACID, ETHYL ESTER, ETHYL ACETATE *97-1*
CAS: 141-78-6
RTECS: AH5425000
Fraction By Weight: 30%
OSHA PEL 1400 MG/CUM
ACGIH TLV: 1400 MG/CUM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ETHANOL (ETHYL ALCOHOL), TECSOL, ALCOHOL, SYNASOL *97-1*
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: 5%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGESTION: GI IRRITANT. ASPIRATION
INTO LUNGS MAY CAUSE CHEMICAL PNEUMONITIS, CAN BE FATAL.
INHALATION: NOSE/THROAT IRRITANT, CNS DEPRESSION. EYES/SKIN: SEVERE
IRRITATION. TOLUENE: REPEATED OVEREXPOSU RE MAY CAUSE LIVER DAMAGE.
REPEATED/PROLONGED OVEREXPOSURE TO SOLVENTS MAY CAUSE PERMANENT
BRAIN/NERVOUS SYSTEM DAMAGE.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, NAUSEA, VOMITING, HEADACHES,
DIZZINESS, CONFUSION
First Aid
First Aid:INGESTION: DON'T INDUCE VOMITING. INHALATION: REMOVE TO FRESH
AIR IMMEDIATELY. IF BREATHING HAS STOPPED, GIVE CPR. KEEP WARM &
QUIET. EYES: FLUSH W/LARGE AMOUNTS OF WATER, CONTINUE FOR 15 MINS.
SKIN: IMMEDIATELY FLUSH W/LARGE AMOUNTS OF WATER. OBTAIN MEDICAL
ATTENTION IN ALL CASES. NOTES TO PHYSICIAN: TREATMENT REQUIRED
SHOULD BE DIRECTED AT THE CONTROL OF SYMPTOMS & CLINICAL
CONDITIONS.
Fire Fighting
Flash Point:24F
Lower Limits:1.7
Upper Limits:19
Extinguishing Media:CO2, DRY CHEMICAL/ALCOHOL FOAM. LARGE: POLYMER
FOAM.
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE, BUT MAY BE USED TO
COOL EXPOSED CONTAINERS WHEN EXPOSED TO EXTREME HEAT. IF WATER IS
USED, FOG NOZZLES ARE PREFERRED.
Unusual Fire/Explosion Hazard:WARNING, FLAMMABLE. OVEREXPOSURE TO
DECOMPOSITION PRODUCTS MAY CAUSE A HEALTH HAZARD. AUTOIGNITION
TEMP: 572F.
Accidental Release
Spill Release Procedures:KEEP SPECTATORS AWAY. ELIMINATE IGNITION
SOURCES. DIKE/CONTAIN LEAK W/INERT MATERIAL. TRANSFER LIQUID TO
COVERED METAL CONTAINERS FOR RECOVERY/DISPOSAL/REMOVE W/INERT
ABSORBENT W/NON-SPARKING TOOLS. A VOID CONTAMINATION OF
SEWERS/STREAMS/GROUNDWATERS.
Handling
Handling and Storage Precautions:DON'T STORE >115F. STORE LARGE
QUANTITIES IN COMPLIANCE W/OSHA 29CFR1910.106. CLOSED CONTAINER
AFTER EACH USE. DON'T WELD/BRAZE/CUT ON EMPTY CONTAINER
Other Precautions:CONTAINERS SHOULD BE GROUNDED & BONDED TO THE
RECEIVING CONTAINER. DON'T TAKE INTERNALLY. EMPTY CONTAINERS MUST
NOT BE WASHED & RE-USED FOR ANY PURPOSE. NEVER USE PRESSURE TO
EMPTY. DRUM ISN'T A PRESS URE VESSEL.
Exposure Controls
Respiratory Protection:RESTRICTED AREA: NIOSH APPROVED CHEMICAL
CARTRIDGE RESPIRATOR. WHEN SPRAYING, USE A MECHANICAL PREFILTER.
CONFINED AREA: NIOSH/MSHA APPROVED AIR SUPPLIED RESPIRATOR. IF TLV
IS EXCEEDED, A PROPERLY FIT TED NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:LOCAL EXHAUST: IN SUFFICIENT VOLUME & PATTERN SO AS TO
MAINTAIN EXPOSURES BELOW NUSIANCE DUST LIMITS & PEL.
Protective Gloves:SOLVENT IMPERMEABLE
Eye Protection:SAFETY SPECTACLES
Other Protective Equipment:EYEWASH FACILITY, SAFETY SHOWER
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING & INHALING THE
CONTENTS MAY BE HARMFUL/FATAL.
Chemical Properties
Boiling Pt:B.P. Text:167F-408F
Melt/Freeze Pt:M.P/F.P Text:-50F
Decomp Temp:Decomp Text:1832F
Vapor Pres:73
Vapor Density:>1
Spec Gravity:0.9
pH:4-7
VOC Grams/Liter:7.59
Evaporation Rate & Reference:SLOWER THAN DIETHYL ETHER
Solubility in Water:SLIGHT
Appearance and Odor:LIQUID W/SOLVENT ODOR
Percent Volatiles by Volume:98
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS, ALKALINE MATERIALS, ACETYL CHLORIDE
Stability Condition to Avoid:EXCESSIVE HEAT >115F & SOURCES OF IGNITION
Hazardous Decomposition Products:BY BURNING/HEATED BY WELDING/CUTTING:
SMOKE, CO, CO2
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS. RCRA HAZARDOUS WASTE NUMBER D001. FLAMMABLE
LIQUID UN1263.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.